Vehicle technical parameters | |
1 | Vehicle technical parameters |
size and quality | |
Car body dimensions mm : length 5370, width 1928 , height 2385 | |
Rescue cabin dimensions mm : length 2 9 00 , width 1 630, height 1750 | |
Wheelbase ( mm ) : 3430 | |
Vehicle equipment mass kg : 2270, 2375 | |
Full load total mass kg : 3100 | |
engine | |
Model: 274920 | |
Fuel type : gasoline | |
Displacement cm3: 1991 | |
Rated output power kw(hp)/rpm : 155/5500 | |
Emission standards: National VI standards | |
Steering system | |
Steering type : Steering wheel | |
Assist mode : hydraulic | |
Steering wheel : front wheel | |
transmission | |
Transmission : 7-speed automatic | |
Top speed km/h: 185 | |
Fuel tank volume (L) : 75 | |
Fuel consumption per 100 kilometers: 10.3 | |
Tires: 2 3 5/ 5 5R1 7 | |
2 | Vehicle standard configuration |
Cab two seats | |
electric windows | |
Driver and co-driver airbags | |
Suspension system: Double wishbone MacPherson independent suspension braking system | |
Central door lock with remote control function | |
Electronic anti-skid system ( ASR ) | |
Anti-lock braking system (ABS) | |
Rear hatchback door | |
Chassis rear suspension: coil spring front inclined positioning independent suspension | |
The blind window on the left door of the medical cabin, the right side, the compartment door, and the rear door are equipped with transparent glass devices | |
The large central control screen includes a reversing image and a driving recorder, and the medical cabin is visible |
Modification configuration form | ||
Roof warning lights and lighting systems | ||
1 | 100W long row of curved blue LED police lights installed on the front of the car roof | 1 set |
2 | A warning light and alarm controller installed in the cab including an external loudspeaker | 1 set |
3 | LED blue square strobe lights are installed at the rear of the roof , and an LED white lighting light is installed in the middle. | 3 cups in total |
4 | A pair of square LED blue strobe lights and LED white lights are installed on the left and right sides of the rear of the car roof. | 4 in total |
5 | LED blue square strobe lights are installed on the left and right sides of the front grille. | 2 cups in total |
electrical equipment | ||
※ 1 : The power distribution of the medical cabin adopts a key ignition control device. When the key is turned to the second gear state, the entire power supply system of the medical cabin automatically connects to the battery power supply, and the entire set of equipment can work normally. When the key is returned to the second gear or pulled out, all The cabin automatically cuts off power (which prevents the battery from being unable to start due to forgetting to turn off electrical appliances). ※ 2 : The medical cabin control system adopts integrated control, and the modified circuit system is equipped with an integrated control main box (to improve the safety of the entire circuit system; repair and replacement of insurance are convenient, fast and easy to operate) | ||
8 | Ring-shaped ultraviolet sterilization lamps and strip-shaped ozone sterilization lamps are installed on the roof of the medical cabin. | 2 cups |
9 | Independent heating and cooling air-conditioning system of the medical cabin (the air-conditioning duct is set up behind the top of the medical cabin, the air outlet fan blades can be adjusted, and the warm air outlet is set up under the oxygen cabinet on the left side of the medical cabin) | 1 set |
10 | A multifunctional and powerful electric ventilation system is installed on the top of the medical cabin | 1 set |
11 | Install lighting in the medical cabin | 5 |
※ 12 | The medical cabin is equipped with a 1000W on-board intelligent pure sine wave inverter system, providing 24- hour uninterrupted power supply . | 1 set |
13 | 220v five-hole socket (including 2 sets of USB interfaces) and 2 sets of DC 12V sockets (including voltage display) are installed on the left side wall of the medical cabin. | 2 sets each |
14 | LED spotlights are installed on the top of the medical cabin ( for use during infusion ) | 1 cup |
body logo | ||
15 | Paste blue or red reflective film and first aid signs around the car body (special ones specified by the user) | 1 set |
Inside the emergency room | ||
※ 16 | The interior of the medical cabin adopts fiberglass integrated interior, aviation version material . It has the following characteristics: 1. Beautiful and practical; 2. Easy to sterilize and disinfect; 3. Light and durable, with good toughness, high strength and long life. | 1 set |
※ 17 | The floor of the medical cabin is made of imported medical LG ocean blue floor leather (anti-slip, acid-resistant, alkali-resistant, anti-corrosion) | 1 set |
18 | A dividing wall is installed between the cab and the medical cabin to separate the front and rear carriages. There is a sliding window on the dividing wall (the window opens on one side), and the glass is transparent for viewing from the front and rear carriages. | 1 set |
19 | Install front and rear intercom system (with megaphone) on the partition wall | 1 set |
20 | Medicine hanging cabinets are installed on the upper left side and front of the medical cabin | 5 sets in total |
twenty one | Oxygen cylinder cabinet at the rear left side of the medical cabin (two 10L oxygen cylinders are installed inside , including pressure reducing valves and stainless steel fixings) | 1 set |
twenty two | A long item cabinet (including transparent plexiglass sliding door) is installed in the front of the oxygen tank in the medical cabin. | 1 set |
twenty three | A set of equipment cabinets is installed in front of the long cabinet on the left side of the medical cabin | 1 set |
twenty four | Two sets of oxygen terminal interfaces and humidification bottles are installed in the middle left side of the medical cabin (can be directly used by patients and ventilators) | 1 set |
25 | The
equipment installation position is reserved on the left side of the medical
cabin (there are equipmen